<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="letter" dtd-version="2.0">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JMIR</journal-id>
      <journal-id journal-id-type="nlm-ta">J Med Internet Res</journal-id>
      <journal-title>Journal of Medical Internet Research</journal-title>
      <issn pub-type="epub">1438-8871</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">v22i4e16205</article-id>
      <article-id pub-id-type="pmid">32319954</article-id>
      <article-id pub-id-type="doi">10.2196/16205</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Letter to the Editor</subject>
        </subj-group>
        <subj-group subj-group-type="article-type">
          <subject>Letter to the Editor</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Authors’ Reply to: Comment on “Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study”</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Eysenbach</surname>
            <given-names>Gunther</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib id="contrib1" contrib-type="author" corresp="yes">
          <name name-style="western">
            <surname>Bredie</surname>
            <given-names>Sebastian J H</given-names>
          </name>
          <degrees>MD, PhD</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <address>
            <institution>Department of Internal Medicine</institution>
            <institution>Radboud University Medical Center</institution>
            <addr-line>PO Box 9101</addr-line>
            <addr-line>Nijmegen, 6500 HB</addr-line>
            <country>Netherlands</country>
            <phone>31 243618819</phone>
            <email>bas.bredie@radboudumc.nl</email>
          </address>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-6973-7540</ext-link>
        </contrib>
        <contrib id="contrib2" contrib-type="author">
          <name name-style="western">
            <surname>de Jong</surname>
            <given-names>Jelske M</given-names>
          </name>
          <degrees>MSc</degrees>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-3612-1053</ext-link>
        </contrib>
        <contrib id="contrib3" contrib-type="author">
          <name name-style="western">
            <surname>van de Belt</surname>
            <given-names>Tom H</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0002-5401-8973</ext-link>
        </contrib>
        <contrib id="contrib4" contrib-type="author">
          <name name-style="western">
            <surname>van Goor</surname>
            <given-names>Harry</given-names>
          </name>
          <degrees>MD, PhD</degrees>
          <xref rid="aff3" ref-type="aff">3</xref>
          <ext-link ext-link-type="orcid">https://orcid.org/0000-0003-0323-4876</ext-link>
        </contrib>
      </contrib-group>
      <aff id="aff1">
        <label>1</label>
        <institution>Department of Internal Medicine</institution>
        <institution>Radboud University Medical Center</institution>
        <addr-line>Nijmegen</addr-line>
        <country>Netherlands</country>
      </aff>
      <aff id="aff2">
        <label>2</label>
        <institution>REshape Center for Innovation</institution>
        <institution>Radboud University Medical Center</institution>
        <addr-line>Nijmegen</addr-line>
        <country>Netherlands</country>
      </aff>
      <aff id="aff3">
        <label>3</label>
        <institution>Department of Surgery</institution>
        <institution>Radboud University Medical Center</institution>
        <addr-line>Nijmegen</addr-line>
        <country>Netherlands</country>
      </aff>
      <author-notes>
        <corresp>Corresponding Author: Sebastian J H Bredie <email>bas.bredie@radboudumc.nl</email></corresp>
      </author-notes>
      <pub-date pub-type="collection">
        <month>4</month>
        <year>2020</year>
      </pub-date>
      <pub-date pub-type="epub">
        <day>22</day>
        <month>4</month>
        <year>2020</year>
      </pub-date>
      <volume>22</volume>
      <issue>4</issue>
      <elocation-id>e16205</elocation-id>
      <history>
        <date date-type="received">
          <day>10</day>
          <month>9</month>
          <year>2019</year>
        </date>
        <date date-type="accepted">
          <day>28</day>
          <month>9</month>
          <year>2019</year>
        </date>
      </history>
      <copyright-statement>©Sebastian J H Bredie, Jelske M de Jong, Tom H van de Belt, Harry van Goor. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 22.04.2020.</copyright-statement>
      <copyright-year>2020</copyright-year>
      <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
        <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on http://www.jmir.org/, as well as this copyright and license information must be included.</p>
      </license>
      <self-uri xlink:href="https://www.jmir.org/2020/4/e16205" xlink:type="simple"/>
      <related-article related-article-type="commentary-article" id="v21i6e11164" ext-link-type="doi" xlink:href="10.2196/11164" vol="21" page="e11164" xlink:type="simple">http://www.jmir.org/2019/6/e11164/</related-article>
      <related-article related-article-type="commentary-article" id="v22i4e15952" ext-link-type="doi" xlink:href="10.2196/15952" vol="22" page="e15952" xlink:type="simple">http://www.jmir.org/2020/4/e15952/</related-article>
      <kwd-group>
        <kwd>cuffless blood pressure</kwd>
        <kwd>pocket devices</kwd>
        <kwd>ambulant blood pressure</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <p>We thank Noud van Helmond and colleagues [<xref ref-type="bibr" rid="ref1">1</xref>] for the critical assessment of our study results.</p>
    <p>In a number of studies, we have recently evaluated the possible value of a handy device (Viatom’s Checkme) for measuring multiple vital parameters, including cuffless blood pressure (BP) determination.</p>
    <p>The Checkme device entered the medical domain after it was originally designed for the consumer market. This makes it very interesting and necessary to scientifically investigate its use in patients.</p>
    <p>After a comparison with a common BP monitor [<xref ref-type="bibr" rid="ref2">2</xref>] and an evaluation of the self-assessment results by admitted patients [<xref ref-type="bibr" rid="ref3">3</xref>], we recently reported the results of its use in ambulatory BP measurement [<xref ref-type="bibr" rid="ref4">4</xref>]. In all these studies, both quantitative and qualitative aspects of the use of the Checkme were scientifically assessed.</p>
    <p>We are aware of the questions about validity and certification raised by van Helmond et al [<xref ref-type="bibr" rid="ref1">1</xref>], and we are pleased that through this platform, we can discuss the issues that we have already covered extensively in our manuscripts. Regarding the validity of Checkme’s systolic BP results, we stated, as discussed extensively in our previous comment on their letter [<xref ref-type="bibr" rid="ref5">5</xref>], that as long as there is no adequate validation protocol specifically for cuffless BP monitors, a formal validation study in accordance with leading protocols is impossible. Thus, in its current form, it is too early to implement a device such as Checkme in daily practice. We found that a real-life comparison currently gives the best insight into the potential value. In their study of both of a smartwatch and a portable health device (Checkme), van Helmond et al [<xref ref-type="bibr" rid="ref6">6</xref>] concluded that the Bodimetrics device was more accurate, possibly due to calibration immediately prior to the study. However, the BP device still failed to meet the accuracy guidelines of the Association for the Advancement of Medical Instrumentation validation protocol, from which van Helmond et al derived their investigation. This protocol assumes that a device should actually be capable of measuring BP without an initial calibration reference measurement. This is peculiar, since it is precisely for the use of cuffless BP monitors that a validation measurement with a traditional BP monitor is required (for estimation of vascular compliance using pulse-oxymetry and electrocardiogram). Only then can an estimate of the BP with these two signals be made. The argument that accuracy improves after a validation measurement taken shortly before a cuffless measurement [<xref ref-type="bibr" rid="ref6">6</xref>] is therefore not valid. Precisely, the choice of reference BP monitors and conditions under which measurement is to be made are not included in the current validation protocols and are the reason that regulatory authorities such as the US Food and Drug Administration could not release Checkme for BP measurement.</p>
    <p>With regard to the interpretation of the accuracy of the absolute BP values in our home measurement study, we disagree with van Helmond et al [<xref ref-type="bibr" rid="ref1">1</xref>]. The clinical practice of treating hypertension is increasingly based on home measurement of BP. Here, measurement variation due to patient and environmental factors is taken for granted by the practitioners, since titration of the treatment based on these home measurements ultimately has a better clinical outcome than treatment based on office measurements. Although the Checkme is user-friendly, disruptive factors such as those found in home measurements cannot be excluded. A comparison of home measurement with different devices illustrates this phenomenon and will never have a strong agreement. That is not our message either. It is all about obtaining many measurement results in order to titrate medical treatment. With only a few reports available, including the study by Schoot et al [<xref ref-type="bibr" rid="ref2">2</xref>], it is too early to promote cuffless measurements on a large scale. However, devices that make use of this technique do appear to be useful at present in, for example, outpatient BP measurement.</p>
    <p>Finally, we agree with van Helmond et al [<xref ref-type="bibr" rid="ref1">1</xref>] that a major advantage of the Checkme is its user-friendliness. All participants were able to take the measurement (12 participants in total). As mentioned in the article, one participant was excluded because the calibration of Checkme did not succeed. The cause for this is unknown, but the measurement itself was performed correctly. Calibration failure was, however, observed in about 10% of the participants in our previous studies [<xref ref-type="bibr" rid="ref2">2</xref>-<xref ref-type="bibr" rid="ref4">4</xref>], and this may be a reason for not using Checkme. The cause for this issue is mostly unclear. If a patient could use the Checkme device, it became clear that he or she started measuring BP much more often and that this self-assessment was a positive point raised in the interviews.</p>
    <p>We hope that our joint effort to scientifically examine these new devices leads to optimization of self-monitoring technology and eventually to improved patient care.</p>
  </body>
  <back>
    <app-group/>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">BP</term>
          <def>
            <p>blood pressure</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <fn-group>
      <fn fn-type="conflict">
        <p>None declared.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>van Helmond</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Jongejan</surname>
              <given-names>WJ</given-names>
            </name>
            <name name-style="western">
              <surname>Hirsh</surname>
              <given-names>RA</given-names>
            </name>
          </person-group>
          <article-title>Comment on "Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients with Hypertension: Mixed Methods Study"</article-title>
          <source>J Med Internet Res</source>
          <year>2020</year>
          <month>04</month>
          <volume>22</volume>
          <issue>4</issue>
          <fpage>e15952</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.jmir.org/2020/4/e15952"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/15952</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Schoot</surname>
              <given-names>TS</given-names>
            </name>
            <name name-style="western">
              <surname>Weenk</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>van de Belt</surname>
              <given-names>TH</given-names>
            </name>
            <name name-style="western">
              <surname>Engelen</surname>
              <given-names>LJLPG</given-names>
            </name>
            <name name-style="western">
              <surname>van Goor</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>Bredie</surname>
              <given-names>SJH</given-names>
            </name>
          </person-group>
          <article-title>A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study</article-title>
          <source>J Med Internet Res</source>
          <year>2016</year>
          <month>05</month>
          <day>05</day>
          <volume>18</volume>
          <issue>5</issue>
          <fpage>e85</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.jmir.org/2016/5/e85/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/jmir.5414</pub-id>
          <pub-id pub-id-type="medline">27150527</pub-id>
          <pub-id pub-id-type="pii">v18i5e85</pub-id>
          <pub-id pub-id-type="pmcid">PMC4873623</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Weenk</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>van Goor</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>van Acht</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Engelen</surname>
              <given-names>LJLPG</given-names>
            </name>
            <name name-style="western">
              <surname>van de Belt</surname>
              <given-names>TH</given-names>
            </name>
            <name name-style="western">
              <surname>Bredie</surname>
              <given-names>SJH</given-names>
            </name>
          </person-group>
          <article-title>A smart all-in-one device to measure vital signs in admitted patients</article-title>
          <source>PLoS One</source>
          <year>2018</year>
          <month>02</month>
          <day>12</day>
          <volume>13</volume>
          <issue>2</issue>
          <fpage>e0190138</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="http://dx.plos.org/10.1371/journal.pone.0190138"/>
          </comment>
          <pub-id pub-id-type="doi">10.1371/journal.pone.0190138</pub-id>
          <pub-id pub-id-type="medline">29432461</pub-id>
          <pub-id pub-id-type="pii">PONE-D-17-18511</pub-id>
          <pub-id pub-id-type="pmcid">PMC5809012</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Ogink</surname>
              <given-names>PA</given-names>
            </name>
            <name name-style="western">
              <surname>de Jong</surname>
              <given-names>JM</given-names>
            </name>
            <name name-style="western">
              <surname>Koeneman</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Weenk</surname>
              <given-names>M</given-names>
            </name>
            <name name-style="western">
              <surname>Engelen</surname>
              <given-names>LJLPG</given-names>
            </name>
            <name name-style="western">
              <surname>van Goor</surname>
              <given-names>H</given-names>
            </name>
            <name name-style="western">
              <surname>van de Belt</surname>
              <given-names>TH</given-names>
            </name>
            <name name-style="western">
              <surname>Bredie</surname>
              <given-names>SJH</given-names>
            </name>
          </person-group>
          <article-title>Feasibility of a New Cuffless Device for Ambulatory Blood Pressure Measurement in Patients With Hypertension: Mixed Methods Study</article-title>
          <source>J Med Internet Res</source>
          <year>2019</year>
          <month>06</month>
          <day>19</day>
          <volume>21</volume>
          <issue>6</issue>
          <fpage>e11164</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.jmir.org/2019/6/e11164/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/11164</pub-id>
          <pub-id pub-id-type="medline">31219050</pub-id>
          <pub-id pub-id-type="pii">v21i6e11164</pub-id>
          <pub-id pub-id-type="pmcid">PMC6607776</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>Bredie</surname>
              <given-names>SJH</given-names>
            </name>
            <name name-style="western">
              <surname>van de Belt</surname>
              <given-names>T</given-names>
            </name>
            <name name-style="western">
              <surname>van Goor</surname>
              <given-names>H</given-names>
            </name>
          </person-group>
          <article-title>Authors' Reply: Comment on "A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study"</article-title>
          <source>J Med Internet Res</source>
          <year>2018</year>
          <month>10</month>
          <day>22</day>
          <volume>20</volume>
          <issue>10</issue>
          <fpage>e12477</fpage>
          <comment>
            <ext-link ext-link-type="uri" xlink:type="simple" xlink:href="https://www.jmir.org/2018/10/e12477/"/>
          </comment>
          <pub-id pub-id-type="doi">10.2196/12477</pub-id>
          <pub-id pub-id-type="medline">30348625</pub-id>
          <pub-id pub-id-type="pii">v20i10e12477</pub-id>
          <pub-id pub-id-type="pmcid">PMC6231735</pub-id>
        </nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
          <person-group person-group-type="author">
            <name name-style="western">
              <surname>van Helmond</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Freeman</surname>
              <given-names>CG</given-names>
            </name>
            <name name-style="western">
              <surname>Hahnen</surname>
              <given-names>C</given-names>
            </name>
            <name name-style="western">
              <surname>Haldar</surname>
              <given-names>N</given-names>
            </name>
            <name name-style="western">
              <surname>Hamati</surname>
              <given-names>JN</given-names>
            </name>
            <name name-style="western">
              <surname>Bard</surname>
              <given-names>DM</given-names>
            </name>
            <name name-style="western">
              <surname>Murali</surname>
              <given-names>V</given-names>
            </name>
            <name name-style="western">
              <surname>Merli</surname>
              <given-names>GJ</given-names>
            </name>
            <name name-style="western">
              <surname>Joseph</surname>
              <given-names>JI</given-names>
            </name>
          </person-group>
          <article-title>The accuracy of blood pressure measurement by a smartwatch and a portable health device</article-title>
          <source>Hosp Pract (1995)</source>
          <year>2019</year>
          <month>10</month>
          <volume>47</volume>
          <issue>4</issue>
          <fpage>211</fpage>
          <lpage>215</lpage>
          <pub-id pub-id-type="doi">10.1080/21548331.2019.1656991</pub-id>
          <pub-id pub-id-type="medline">31423912</pub-id>
        </nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>